L1PH Series Uninterruptible Power Supplies L1PH
Page 1 of 2
14.0 kVA Single Phase UPS System
Operates incandescent, magnetic and electronic ballast fluorescent, high power factor compact fluorescent, and high intensity discharge (HID) lamp types.
33.0”
83.8 cm
34.0”
86.4 cm
30.0”
76.2 cm
33.0”
83.8 cm
Battery
Cabinet
70.0”
177.8 cm
Electronics
Cabinet
43.5”
110.5 cm
How to Specify:
SERIES
INPUT
VOLTAGE
SYSTEM
TYPE
BASE
SIZE
BATTERY
TYPE
OUTPUT
VOLTAGE
OUTPUT
CKT BRKRS
# ON 2ND
VOLTAGE
NORMALLY
OFF LOAD
# OF
NOL
NOL
VOLTAGE
1
14.0 = 14.0 kVa S = Sealed
1 = 120 V
Y = Hardwire
A = 1 0CB
B = 2 0CB
C = 3 0CB
0
1
2
3
4
A = No
B = Yes
C = Yes w/ Time Terminal
0 = No NOL
Y = Hardwire
X = None
A = 1st
B = 2nd
I = ETL Listed
to UL 924 for
Emergency
Lighting
2 = 208 V
3 = 240 V
4 = 277 V
Z = Special
Voltage
L1PH = Single
Phase
Uninterruptible
Power
Supplies
Lead Calcium 2 = 208 V
3 = 240 V
4 = 277 V
5 = 120/208 V D = 4 0CB
6 = 120/240 V E = 5 0CB
Delay Timer
1 = 1
2 = 2
3 = 3
Applications
5
(Consult
7 = 120/277 V F = 6 0CB
6
7
8
9
4 = 4
5 = 5
6 = 6
7 = 7
Factory)
Z = Special
Voltage
(Consult
G = 7 0CB
H = 8 0CB
J = 9 0CB
NOTE: Input circuit
breaker not available.
Input switch is
Factory)
K = 10 0CB
L = 11 0CB
M = 12 0CB
N = OCBA1
P = OCBA2
R = OCBA3
S = OCBA4
T = OCBA5
U = OCBA6
V = OCBA7
W = OCBA8
X = OCBA9
10
11
8 = 8
9 = 9
10 = 10
11 = 11
12 = 12
standard.
Overall Characteristics
Electrical
•
•
•
•
•
•
•
86% throughput efficiency
•
•
•
•
•
•
•
•
•
•
•
Sine Wave Output
Operating temperature range 32°F (0°C) to 104°F (40°C)
Internal maintenance by-pass is standard
Main load disconnect switch standard
Double conversion, no interruption
Standard backup time of 90 minutes, other run times optional
Output circuit breakers and normally-off loads optional
Completely solid-state Pulse Width Modulation (PWM) inverter
16-bit microprocessor control
Input power factor correction maintains power factor at 0.99
Transient response ≤ 5%; Recovery time, 10 mS (100% load step)
3:1 crest factor capability
Inverter output distortion ≤ 2.5% THD (at unity power factor)
Output voltage regulation ±6% of nominal at full load
Frequency within ±0.05% of nominal
Housing
•
•
•
Free standing, NEMA 1 enclosure
Acid resistant powder coat finish
Multiple conduit entries
Inverter efficiency ≥ 84%
Load power factor capability is 0.5 leading to 0.5 lagging
(Continued on page 2)
Metering/Controls
Standard
•
Alpha-numeric front panel display with 14 metered measurements and
53 messages/alarms
Normal, caution and alarm indicating LEDs
Audible failure alarms with silence switch
Dry contact for remote failure alarm
•
•
•
•
•
“D” type 9-pin computer interface connector (see pin config. on back)
Programmable battery monitor with alarm
Optional
•
•
Diagnostics software for remote computer (PC) monitoring and control
Stand-alone remote display mimics all measurements, indications and
alarms shown on the front panel display
Lightolier a Genlyte Thomas Company
•
Additional RS-232 input/output port for remote monitoring and system
control
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • D0504
|